How to attach / detach the Right angle head for MVR with a manual tool

1. 1. As shown in the figure, hook the tool attachment / detachment jig (accessory at the time of delivery) on the horseshoe of the Right angle head.

2. 2. Tighten the bolts with a hex wrench, compress the springs of the tool clamp device and remove the tool.
(It is necessary to push in about 10 mm to remove the tool)

Note 1. When removing the tool, wear safety equipment and be careful not to pinch your limbs or fingers.

Note 2. Do not work alone as the tools are heavy.
Be sure to work with two or more people, and handle the tools with safety equipment.
For tools that are difficult to hold, be sure to remove the tool while receiving it with a stable jig.

Note 3. The work of tightening bolts (loosening tools) requires a large amount of force.
Make sure that your feet do not slip so that you do not accidentally tip over when tightening the bolts.
Also, wear safety equipment to prepare for injuries in the event of a fall.

Note 4. If it is difficult to loosen the tool manually, options such as hydraulic jigs are also available.
We are preparing it, so please order it separately.